Job Detail

Structural Engineering Review Requirement: Gantry Tower Design Verification

End Date: Jun 02 2025

NRP 2000 - 4000

2 bids
We are seeking a qualified Structural Engineer with proven expertise in tower design using STAAD software. The task involves reviewing a gantry tower design by independently from provided model to verify the results provided in the submitted design report. The reviewer is expected to analyze the structural performance, validate the calculations, and provide technical comments or recommendations if discrepancies are found. The complete review, including model verification and feedback, must be submitted within 3 days from the date of assignment.
2 freelancer(s) are bidding
Damping
@Damping

I have worked in tower design from Staad software for different projects in Nepal. Reviewing a staad model is relatively easier task. I will also be providing the review notes if found necessary. I hope I will smoothly meet the requirement. Thanks you.

more
3000 in 3 days
★☆☆☆☆
oprakashgupta06@gmail.com
@oprakashgupta06@gmail.com

Dear Sir, I am excited to submit my application for the Gantry Tower Design Verification assignment. With over seven years of experience in structural engineering for substation and transmission infrastructure, I have successfully delivered gantry, rigid bus support, and equipment support structure designs for clients in Nepal, India, and the United States. My expertise includes both primary design and independent third-party reviews using STAAD.Pro, supported by a strong understanding of national and international codes. Code Proficiency: I bring deep familiarity with the following standards: • India: • IS (Part 1/Sec 1 & 2): – Design of steel structures for transmission line and substation gantries • IS : – General steel design using limit state method • IS (Parts 1–3) – Load calculations for dead, live, and wind loads • IS : – Seismic load analysis • USA: • AISC – Substation Structures Specification (specific to design of steel structures in substations) • AISC – Specification for Structural Steel Buildings • ASCE – Minimum Design Loads and Associated Criteria for Buildings and Other Structures This dual-code experience enables me to perform comprehensive and compliant structural evaluations, particularly in hybrid-code projects or when validating designs for international clients. For this assignment, I will: • Independently verify the provided STAAD model and structural design report. • Validate load cases, member adequacy, and connection detailing based on applicable codes. • Highlight any discrepancies and provide actionable technical feedback. • Deliver a clear, professional review report within 3 days of assignment. My recent work with a U.S.-based engineering firm involved reviewing substation structures for both domestic and international utility clients, giving me hands-on experience in aligning AISC and IS standards to meet project goals. Thank you for considering my proposal. I would be glad to share relevant samples or credentials upon request and look forward to the opportunity to contribute to your project. Best regards, Om Prakash Gupta Senior Structural Engineer | ???? + ???? LinkedIn Profile

more
3900 in 3 days
★☆☆☆☆